Publikasjoner
NIBIOs ansatte publiserer flere hundre vitenskapelige artikler og forskningsrapporter hvert år. Her finner du referanser og lenker til publikasjoner og andre forsknings- og formidlingsaktiviteter. Samlingen oppdateres løpende med både nytt og historisk materiale. For mer informasjon om NIBIOs publikasjoner, besøk NIBIOs bibliotek.
2004
Forfattere
Jørn Kristian Lileng Erlend Ystrøm HaartveitSammendrag
Forest roads ensure access to standing timber and their standards may restrict the opportunity set for efficient logistical solutions. Traditionally, the objective of road investments has been maximisation of returns for the landowner.Investments in forest roads in Norway are subsidised by the Norwegian government. These subsidies should preferably be allocated to projects creating the best premises for efficient log supply. The total cost approach evaluates costs using a holistic perspective. In this paper we use this approach to evaluate the profitability of investments in forest roads so that the total costs for log supply to the industry are minimised.The distribution of standing timber in the catchment area of the forest road is also taken into account. The results show that the sum of costs for road construction, harvesting and forwarding account for more than 99% of the total costs, compared to less than 1% for the sum of log hauling costs. Differentiation of forest road standards is more appropriate in situations where the volume of standing timber decreases in remote areas of the forest road network.
Sammendrag
A method for determination of the climate gases CH4, CO2 and N2O in air samples and soil atmosphere was developed using GC-MS. The method uses straightforward gas chromatography (separation of the gases) with a mass spectrometric detector in single ion mode (specific determination).The gases were determined with high sensitivity and high sample throughput (18 samples h1). The LOD (3) for the gases were 0.10 L L1 for CH4, 20 L L1 for CO2 and 0.02 L L1 for N2O. The linear range (R2 = 0.999) was up to 500 L L1 for CH4, 4000 L L1 for CO2 and 80 L L1 for N2O. The samples were collected in 10 mL vials and a 5 L aliquot was injected on column.The method was tested against certified gas references, the analytical data gave an accuracy within 5% and a precision of 3%. The presence of 10% by volume of C2H2 (often used experimentally to prevent N2 formation from N2O) did not interfere with detection for the targeted trace gases.
Sammendrag
Det er ikke registrert sammendrag
Forfattere
Kjersti Holt HanssenSammendrag
Det er ikke registrert sammendrag
Forfattere
Kaj Bo Veiersted Tove M. ØstensvikSammendrag
Det er ikke registrert sammendrag
Forfattere
Åsmund AsdalSammendrag
Det er ikke registrert sammendrag
Forfattere
Knut Langeland Åsmund AsdalSammendrag
Det er ikke registrert sammendrag
Forfattere
Terje BirkelandSammendrag
Det er ikke registrert sammendrag
Forfattere
Ingvald RøsbergSammendrag
Det er ikke registrert sammendrag
Forfattere
Severin WoxholttSammendrag
Det er ikke registrert sammendrag